GTI Nodes operation procedure¶
Prerequisites¶
Install NuScribe on your computer, and NuSite on your Android tablet/smartphone. Check that you have the same software version on both sides.
Required computer configuration
- Operating System: Windows 10 Pro x64 Version 1809 Build 17763.107 or later
- CPU: 64-bit, 2GHz, 2 cores
- RAM: 32GB
- Hard Drive: 1TB SSD
- USB minimum 1 USB-3 port
- Wi-Fi: required for NuWeb/NuSi
You need to setup your computer network configuration to be able to communicate with the Data Management Panel (DMP).
- Go in your
Network & Internet Settings
, change ethernet adapter options - Change IPv4 properties to a static IP address
- Use the following IP address
10.10.0.1
(or anything between1
and10
for the last segment) - Subnet mask should be
255.0.0.0
and others left empty (default) - Select OK
Warning
Never update Java on your PC as it will potentially break down NuScribe.
Prepare your acquisition¶
Setup your project in NuScribe¶
-
Create new project in NuScribe
Navigation
Navigate through options by clicking on the arrow on the right of the screen
-
Set survey projection to
WGS84
-
Import survey
.SP1
file [optional]On the fly
Importing a survey file is not necessary if you carry out
on the fly
survey (i.e. if you don't know beforehand where you will collect data in the field). -
At the bottom right, click on
Create
and wait untilSuccess!
appears on the screen. Click onOK
to open the new project.
Synchronize your computer and tablet/smartphone¶
-
You must be connected to the same WiFi network on both the tablet and the computer, with NuScribe open.
-
Open the NuSite app, then synchronize users using the following credentials
- id:
nuseis
- password:
123
- id:
-
Go to
DATA
->NUWEB SYNC
. It should now say that NuWeb is online and connected to the current project opened in NuScribe.Warning
If you changed the WiFi network since last sync, you might need to reset the IP address in NuSite. Get the IPv4 address of your WiFi adapter by typing
ipconfig
in the command prompt. -
Select
Synchronize all
, then pressOK
once it's done.Last Update
should now display the current date and time.
In the field¶
Install and start up the nodes¶
-
Install the nodes along the desired profile.
Setting up the nodes
Depending on the field conditions, you might want to use either:
- the manual deployment tool to dig a perfect-fitted hole for the node
- the custom blue land bases with spikes
-
Use the bump tool to deploy the nodes. Slide the bump tool over the node cap and hold it for about one second until it starts flashing white, then quickly remove it while holding the node firmly into the ground.
Warning
Make sure the bump tool is sliding parallel to the node cap. There is a risk to bend (and eventually break) the metal parts inside the bump tool.
GPS fix
Once deployed, the node will look for GPS signal fix, then will start recording data automatically.
-
In the NuSite app, go to
NRU
, select each deployed node and click onAssign
to set line and station number. You might need to manually deploy some nodes. Select the node in NuSite, then click onConnect
, then your node will turn blue. Once connected, you can deploy it with the app.Info
Each of our nodes has been assigned with a fixed ID between 1 and 130, sorted by increasing serial number. In the NuSite app, you can sort nodes by serial number, and refer to the ID/Serial Number correspondence list to ease assignment in the field.
ID / Serial numbers list
{{ read_csv('content/nru_serial_numbers.csv',floatfmt=("1.0f","1.0f")) }}
Warning
Line and station assignment in the field can take time. Although recommended, it is not mandatory. If you know which node ID/serial number corresponds to which field station (e.g. written on a field notebook), you will be able to assign it later when back in the lab. The process is described below, but note that it is not straightforward.
Collect shots¶
-
Connect the EVR-2 GPS seismic event recorder to the trigger and hammer source.
-
Start the EVR-2 app on the tablet, then connect to the EVR-2 device.
-
In
Settings
, selectClear shot history
andReset FFID
at the start of a new survey to make sure you start with a clean list. -
Go in
Generate points
to create the list of shot stations and line numbers that you want to collect.Warning
To ease deployment, we usually use separate numbering for node stations and shot stations. For instance, if you use 90 nodes, and record shots in between each nodes and at both ends (i.e. 91 shots total), you will have node stations ranging from 1 to 90 in the NuSite app, and shot stations ranging from 1 to 91 in the EVR-2 app. Make sure you keep track of the correspondance between station number and position along your profile or grid coordinates in the field.
-
Go in
Shots
, then check that you start with the correct Line and Station number. -
Collect shots along the line (use stack option if multiple shots at the same station, or choose correct station manually).
Info
You can discard bad shots in
Shot history
in the EVR-2 app (long click, thenomit shot
), and export only correct shot timestamps.
End survey¶
- If collecting a new line with the same station assignment, you don't need to undeploy the nodes. Simply move them to their new location, and change line number in EVR-2 app.
Warning
Make sure to keep the nodes upright when moving them to a new line to avoid undeploying them.
- If ending the survey, simply store the nodes upside down in the carrying bag. They will undeploy automatically.
Warning
If you used the blue land base with spikes, use a small hammer to remove them from the nodes. Hit them gently with the hammer, making sure you don't damage the node.
- In EVR-2 app., go in
Shot history
, thenOutput all shots
with the button at the bottom-right of the screen.
Download the data¶
Synchronize your computer and tablet/smartphone¶
-
Start NuScribe and select current project.
-
Synchronize the NuSite app (cf. [Preparing your survey]). Deployments with associated Line/Station assignments should now appear in
View
->Deployments
.
Download data¶
-
In
Data Panels
->DMPs
, selectDownload
sequence, thenEdit Sequence
to check output directory inSeismic
. Create a directory inDocuments/Data/your_survey/nodes_data
and select it.Warning
Make sure
Output raw file
is NOT checked. -
Insert the first 8 [or 10] nodes in the DMP rack
-
Launch the sequence with the green arrow. Nodes will turn yellow, then display
Serial Number
, and finally turn green once data download is over.Info
You can live check the sequence status by opening
DMP Sequence panel
, then right clicking on a blue cup on the rack panel and selectingDisplay Command Sequence
. If a DMP slot is malfunctionning (i.e. serial number doesn't show), simply try again in a different slot. -
Repeat steps 2 and 3 until all nodes data have been downloaded.
Import survey parameters¶
Shot timestamp file conversion¶
- Connect smartphone to the PC to download the EVR-2 file (named
OB_date&time.txt
). Store the file inDocuments/Data/your_survey/timestamps
- Start
Visual Studio Code
and run the python scriptevr2_to_nuscribe.py
to convert the EVR-2 file in two files (OB_date&time.sp1
andOB_date&time.sbs_ffid
) that will be later required in NuScribe. At the beginning of the script, change the path of the EVR-2 file you want to convert. The new files will be stored in the same directory.
Import survey parameters in NuScribe¶
-
In NuScribe, go in
View
->Receivers
, then click onCreate points from deployments
(red flag with green arrow) to generate node station/line numbers. -
In
View
->Survey Files
, import theOB_date&time.sp1
as aSource SP1
file type. Source stations should now appear asPlanned
inView
->Source
.Warning
Make sure you select
Source
instead ofReceiver
(which is the default option). -
In
View
->Sercel Files
, click onAdd Sercel Observer's log file
and selectOB_date&time.sbs_ffid
, then click onCreate acquired shots from observer logs
. Shots should now appear inView
->Acquired shots
.
Export SEGY files¶
Set up the workflow¶
-
Go in
Data Panels
->Flows
-
Select the input data directory containing raw data (cf [Download data]), and the output data directory in which you want to save your SEGY files (usually
Documents/Data/your_survey/segy
). -
Select Domain
Source
-
Select Start Time and End Time (usually a day before the start a of the survey, and a day after the end).
-
Select
VIBRO
inShot Process Name
. -
In
Workers
(bottom left menu), select Process TypeRead Dat
, then adjust output parameters (bottom right menu). All boxes should be checked exceptuse relational template
. -
Sample interval should match the one defined in the nodes (250 µs by default).
-
Shift time by -5000 µs to add a pre-trigger delay.
-
Save the flow (top left). Default name is
DefaultFlow
.
Export SEGY files in NuScribe¶
-
Go to
Data Panels
->Manager
andCreate NuTask
-
Select
Flow Work
in NuTask Type list, thenFlowName
(cf step 9 above) and checkAll Source
box. -
Click on
Show Job Count
at the bottom of the page. It should now display the correct number of sources.Node
If multiple sources are located at the same location, it will show the number of position instead of the number of shots. Yet, it should still create the correct number of segy files.
-
Press
OK
to start creating the files. -
Your files will be stored in
Documents/Data/your_survey/segy/FlowName/Read Dat